onsdag 3 december 2014

The possibility

The possibility to include the production of domestic hot water to the SPF calculations is also a necessity in future calculation models. It should also be described how this shall be measured in tests alternatively, how the amount of produced domestic hot water shall be estimated. Today there are two main ways how to do the measurements, including the losses or not (one can measure the amount of energy that is obtained by tappings or the amount of tap water the heat pump is producing). A lot of work has already been done in this respect in the IEA HPP Annex 28 [13]. Also, there is a CEN standard on the way on how to treat DHW production. This standard however does not take into consideration combined heating and DHW production.
 Accumulators should be possible to include in the model.  
 A model must contain clear system boundaries for what is to be included in the calculations and how measurements are performed. As a basis, the system boundaries presented in the SEPEMO project [12] is recommended.
 The model must be transparent so it is possible to follow and understand the calculations. The studied models all contain parts that are more or less transparent. For example how the estimation of the number of equivalent heating hours is performed is not shown in any method

Inga kommentarer:

Skicka en kommentar